Mackinder
@mackinder
New Member
Joined: Feb 15, 2024
Topics: 7 / Replies: 19
Reply
RE: Morph Channel controlled by multiple masters

I don’t think this is possible?

13 years ago
Forum
Reply
RE: paramwire.disconnect troubles

Hey man, I got a chance to get back to this and this works a charm. Working back from the slave I’ve found using ref.dependents I can then find the m…

13 years ago
Forum
Reply
RE: paramwire.disconnect troubles

Oh I see! I was expecting to see a direct result from the controller itself, I didn’t realise I was finding something to match. D’oh! I don’t have …

13 years ago
Forum
Reply
RE: paramwire.disconnect troubles

Hey man, cheers for continuing to help me. After asking for the slaveAnimation I’m given the result of “Controller:Bezier_Float”?

13 years ago
Forum
Reply
RE: paramwire.disconnect troubles

Okay so… refs.dependents $.pos.controller.Y_Position.controller [#Limited_Controller__Bezier_Float].controller Which returns: #(Controller:Float_Wi…

13 years ago
Forum
Reply
RE: paramwire.disconnect troubles

Bugger, I was entering in the wrong position in the post before; it’s actually returning: #(Controller:Float_Wire, ReferenceTarget:ParamBlock, Morphe…

13 years ago
Forum
Reply
RE: paramwire.disconnect troubles

But then goes back to returning: #(Controller:Float_Limit, Controller:Position_XYZ, Controller:Position_Rotation_Scale, $Circle:JoystickNameCircleCon…

13 years ago
Forum
Reply
RE: paramwire.disconnect troubles

Sure no problem. paramWire.connect pickJS.object.pos.controller.X_Position.controller[#Limited_Controller__Bezier_Float] pickMesh.object.modifiers[#…

13 years ago
Forum
Reply
RE: paramwire.disconnect troubles

Aye I’ve not got a space. Here’s a shot of exactly how I’m executing that line:

13 years ago
Forum
Reply
RE: paramwire.disconnect troubles

Hum… that doesn’t seem to work for me, I get this in the listener: — No “”get”” function for 5.0

13 years ago
Forum
Reply
RE: paramwire.disconnect troubles

Oh I see, so: refs.dependson $.pos.controller.Y_Position.controller.upper_limit.controller Is what I’m after? After executing that I’m given: #(Re…

13 years ago
Forum
Reply
RE: paramwire.disconnect troubles

Ah thanks! I was looking at the paramWire stuff. So I’ve been looking into this and I can’t just supply the same thing I’ve supplied for parameter c…

13 years ago
Forum
Reply
RE: paramwire.disconnect troubles

Seeing as this thread is already active, does anyone happen to know how to find out what’s on the other end of a controller that is set-up via wire pa…

13 years ago
Forum
Reply
RE: paramwire.disconnect troubles

Saved my ass again! Thanks man!

13 years ago
Forum
Topic
Forum
Replies: 36
Views: 55
Page 1 / 2